General parameters | |||
Type | AL5F | ||
Band | 5 GHz | ||
Band | Licensed / License free | ||
Frequency range (GHz) | 4.400 - 5.875 / 5.470 - 5.725 / 5.725 - 5.850 / 5.725 - 5.875 | ||
Duplex spacing (MHz) | 90, 186, 300, 312 or software configurable | ||
Channel bandwidth (MHz) | 3.5 to 112 for 4.400 - 5.875 / 5.470 - 5.725 / 3.5 to 56 for 5.725 - 5.850 / 5.725 - 5.875 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 900 for MP400 (5 to 460 for MP300) full duplex | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Salomon | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters |
|||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power max. (dBm) (5.725-5850 / 4.400-5875) |
3.5 MHz / QPSK | 5 | -91 | 10 / 18 |
3.5 MHz / 8QAM | 8 | -88 | 10 / 18 |
3.5 MHz / 16QAM | 11 | -86 | 10 / 18 |
3.5 MHz / 32QAM | 14 | -82 | 10 / 18 |
3.5 MHz / 64QAM | 17 | -79 | 10 / 18 |
3.5 MHz / 128QAM | 20 | -76 | 10 / 18 |
3.5 MHz / 256QAM | 22 | -74 | 10 / 18 |
3.5 MHz / 512QAM | 25 | -70 | 10 / 18 |
3.5 MHz / 1024QAM | 27 | -67 | 10 / 18 |
7 MHz / QPSK | 11 | -88 | 10 / 18 |
7 MHz / 8QAM | 16 | -86 | 10 / 18 |
7 MHz / 16QAM | 22 | -82 | 10 / 18 |
7 MHz / 32QAM | 28 | -79 | 10 / 18 |
7 MHz / 64QAM | 33 | -77 | 10 / 18 |
7 MHz / 128QAM | 40 | -74 | 10 / 18 |
7 MHz / 256QAM | 44 | -71 | 10 / 18 |
7 MHz / 512QAM | 50 | -68 | 10 / 18 |
7 MHz / 1024QAM | 55 | -65 | 10 / 18 |
10 MHz / QPSK | 16 | -88 | 10 / 18 |
10 MHz / 8QAM | 23 | -86 | 10 / 18 |
10 MHz / 16QAM | 31 | -82 | 10 / 18 |
10 MHz / 32QAM | 40 | -78 | 10 / 18 |
10 MHz / 64QAM | 47 | -76 | 10 / 18 |
10 MHz / 128QAM | 57 | -73 | 10 / 18 |
10 MHz / 256QAM | 62 | -70 | 10 / 18 |
10 MHz / 512QAM | 71 | -67 | 10 / 18 |
10 MHz / 1024QAM | 78 | -64 | 10 / 18 |
14 MHz / QPSK | 25 | -85 | 10 / 18 |
14 MHz / 8QAM | 35 | -82 | 10 / 18 |
14 MHz / 16QAM | 46 | -79 | 10 / 18 |
14 MHz / 32QAM | 58 | -76 | 10 / 18 |
14 MHz / 64QAM | 69 | -74 | 10 / 18 |
14 MHz / 128QAM | 81 | -71 | 10 / 18 |
14 MHz / 256QAM | 92 | -69 | 10 / 18 |
14 MHz / 512QAM | 104 | -65 | 10 / 18 |
14 MHz / 1024QAM | 115 | -62 | 10 / 18 |
20 MHz / QPSK | 36 | -83 | 10 / 18 |
20 MHz / 8QAM | 50 | -80 | 10 / 18 |
20 MHz / 16QAM | 65 | -77 | 10 / 18 |
20 MHz / 32QAM | 83 | -75 | 10 / 18 |
20 MHz / 64QAM | 100 | -72 | 10 / 18 |
20 MHz / 128QAM | 115 | -69 | 10 / 18 |
20 MHz / 256QAM | 131 | -67 | 10 / 18 |
20 MHz / 512QAM | 148 | -63 | 10 / 18 |
20 MHz / 1024QAM | 165 | -60 | 10 / 18 |
28 MHz / QPSK | 50 | -81 | 10 / 18 |
28 MHz / 8QAM | 69 | -79 | 10 / 18 |
28 MHz / 16QAM | 92 | -76 | 10 / 18 |
28 MHz / 32QAM | 116 | -74 | 10 / 18 |
28 MHz / 64QAM | 139 | -70 | 10 / 18 |
28 MHz / 128QAM | 162 | -68 | 10 / 18 |
28 MHz / 256QAM | 185 | -65 | 10 / 18 |
28 MHz / 512QAM | 208 | -62 | 10 / 18 |
28 MHz / 1024QAM | 230 | -58 | 10 / 18 |
40 MHz / QPSK | 66 | -81 | 10 / 18 |
40 MHz / 8QAM | 100 | -78 | 10 / 18 |
40 MHz / 16QAM | 132 | -75 | 10 / 18 |
40 MHz / 32QAM | 165 | -72 | 10 / 18 |
40 MHz / 64QAM | 200 | -69 | 10 / 18 |
40 MHz / 128QAM | 232 | -67 | 10 / 18 |
40 MHz / 256QAM | 265 | -63 | 10 / 18 |
40 MHz / 512QAM | 300 | -60 | 10 / 18 |
40 MHz / 1024QAM | 330 | -57 | 10 / 18 |
56 MHz / QPSK | 100 | -78 | 10 / 18 |
56 MHz / 8QAM | 139 | -76 | 10 / 18 |
56 MHz / 16QAM | 185 | -74 | 10 / 18 |
56 MHz / 32QAM | 232 | -71 | 10 / 18 |
56 MHz / 64QAM | 278 | -68 | 10 / 18 |
56 MHz / 128QAM | 324 | -65 | 10 / 18 |
56 MHz / 256QAM | 370 | -62 | 10 / 18 |
56 MHz / 512QAM | 417 | -59 | 10 / 18 |
56 MHz / 1024QAM | 459 | -56 | 10 / 18 |
80 MHz / QPSK | 132 | -78 | 10 / 18 |
80 MHz / 8QAM | 200 | -75 | 10 / 18 |
80 MHz / 16QAM | 265 | -71 | 10 / 18 |
80 MHz / 32QAM | 330 | -69 | 10 / 18 |
80 MHz / 64QAM | 400 | -66 | 10 / 18 |
80 MHz / 128QAM | 463 | -63 | 10 / 18 |
80 MHz / 256QAM | 530 | -60 | 10 / 18 |
80 MHz / 512QAM | 600 | -57 | 10 / 18 |
80 MHz / 1024QAM | 660 | -54 | 10 / 18 |
112 MHz / QPSK | 184 | -77 | 10 / 18 |
112 MHz / 8QAM | 277 | -74 | 10 / 18 |
112 MHz / 16QAM | 369 | -70 | 10 / 18 |
112 MHz / 32QAM | 461 | -68 | 10 / 18 |
112 MHz / 64QAM | 553 | -65 | 10 / 18 |
112 MHz / 128QAM | 646 | -61 | 10 / 18 |
112 MHz / 256QAM | 740 | -58 | 10 / 18 |
112 MHz / 512QAM | 830 | -55 | 10 / 18 |
112 MHz / 1024QAM | 900 | -53 | 10 / 18 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antenna connection |
|||
Connector type | N | ||
Power supply | |||
Power supply | 48 V DC (36-72) | ||
Power consumption | Up to 35 W | ||
Temperature range | |||
Outdoor unit | -33 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 309 x 175 mm / 6.7 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg |
General parameters | |||
Type | AL6F | ||
Band | 6 GHz | ||
Band | Licensed | ||
Frequency range (GHz) | 5.850 - 7.125 | ||
Duplex spacing (MHz) | 150, 160, 170, 180, 240, 252.04, 266, 340 | ||
Channel bandwidth (MHz) | 3.5 to 112 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 900 for MP400 (5 to 460 for MP300) full duplex | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Salomon | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters | |||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power max. (dBm) |
3.5 MHz / QPSK | 5 | -94 | 22 |
3.5 MHz / 8QAM | 8 | -90 | 22 |
3.5 MHz / 16QAM | 11 | -88 | 22 |
3.5 MHz / 32QAM | 14 | -83 | 22 |
3.5 MHz / 64QAM | 17 | -80 | 20 |
3.5 MHz / 128QAM | 20 | -77 | 20 |
3.5 MHz / 256QAM | 22 | -74 | 20 |
3.5 MHz / 512QAM | 25 | -71 | 20 |
3.5 MHz / 1024QAM | 27 | -66 | 20 |
7 MHz / QPSK | 11 | -90 | 22 |
7 MHz / 8QAM | 16 | -88 | 22 |
7 MHz / 16QAM | 22 | -84 | 22 |
7 MHz / 32QAM | 28 | -81 | 22 |
7 MHz / 64QAM | 33 | -78 | 20 |
7 MHz / 128QAM | 40 | -75 | 20 |
7 MHz / 256QAM | 44 | -72 | 20 |
7 MHz / 512QAM | 50 | -69 | 20 |
7 MHz / 1024QAM | 55 | -65 | 20 |
14 MHz / QPSK | 25 | -85 | 22 |
14 MHz / 8QAM | 35 | -83 | 22 |
14 MHz / 16QAM | 46 | -81 | 22 |
14 MHz / 32QAM | 58 | -77 | 22 |
14 MHz / 64QAM | 69 | -75 | 20 |
14 MHz / 128QAM | 81 | -72 | 20 |
14 MHz / 256QAM | 92 | -69 | 20 |
14 MHz / 512QAM | 104 | -66 | 20 |
14 MHz / 1024QAM | 115 | -63 | 20 |
28 MHz / QPSK | 50 | -82 | 22 |
28 MHz / 8QAM | 69 | -81 | 22 |
28 MHz / 16QAM | 92 | -77 | 22 |
28 MHz / 32QAM | 116 | -73 | 22 |
28 MHz / 64QAM | 139 | -72 | 20 |
28 MHz / 128QAM | 162 | -69 | 20 |
28 MHz / 256QAM | 185 | -66 | 20 |
28 MHz / 512QAM | 208 | -64 | 20 |
28 MHz / 1024QAM | 230 | -61 | 20 |
40 MHz / QPSK | 66 | -82 | 22 |
40 MHz / 8QAM | 100 | -80 | 22 |
40 MHz / 16QAM | 132 | -76 | 22 |
40 MHz / 32QAM | 165 | -74 | 22 |
40 MHz / 64QAM | 200 | -71 | 20 |
40 MHz / 128QAM | 232 | -68 | 20 |
40 MHz / 256QAM | 265 | -65 | 20 |
40 MHz / 512QAM | 300 | -62 | 20 |
40 MHz / 1024QAM | 330 | -59 | 20 |
56 MHz / QPSK | 100 | -80 | 22 |
56 MHz / 8QAM | 139 | -78 | 22 |
56 MHz / 16QAM | 185 | -75 | 22 |
56 MHz / 32QAM | 232 | -72 | 22 |
56 MHz / 64QAM | 278 | -69 | 20 |
56 MHz / 128QAM | 324 | -67 | 20 |
56 MHz / 256QAM | 370 | -64 | 20 |
56 MHz / 512QAM | 417 | -60 | 20 |
56 MHz / 1024QAM | 459 | -58 | 20 |
80 MHz / QPSK | 132 | -80 | 22 |
80 MHz / 8QAM | 200 | -76 | 22 |
80 MHz / 16QAM | 265 | -74 | 22 |
80 MHz / 32QAM | 330 | -70 | 22 |
80 MHz / 64QAM | 400 | -68 | 20 |
80 MHz / 128QAM | 463 | -64 | 20 |
80 MHz / 256QAM | 530 | -61 | 20 |
80 MHz / 512QAM | 600 | -59 | 20 |
80 MHz / 1024QAM | 660 | -55 | 20 |
112 MHz / QPSK | 184 | -77 | 22 |
112 MHz / 8QAM | 277 | -75 | 22 |
112 MHz / 16QAM | 369 | -72 | 22 |
112 MHz / 32QAM | 461 | -69 | 22 |
112 MHz / 64QAM | 553 | -66 | 20 |
112 MHz / 128QAM | 646 | -62 | 20 |
112 MHz / 256QAM | 740 | -60 | 20 |
112 MHz / 512QAM | 830 | -55 | 20 |
112 MHz / 1024QAM | 900 | -52 | 20 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antennas | |||
0.65 m gain mid band (dBi) | 30 | ||
0.90 m gain mid band (dBi) | 33 | ||
1.20 m gain mid band (dBi) | 36 | ||
Class | ETSI Class 2 or 3 | ||
Polarization | Vertical or horizontal | ||
Power supply | |||
Power supply | 48 V DC (36-72) | ||
Power consumption | Up to 25 W | ||
Temperature range | |||
Outdoor unit | -33 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 301 x 133 mm / 5.1 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg | ||
Antenna 0.65 m | 8.3 kg | ||
Antenna 0.90 m | 26 kg | ||
Antenna 1.20 m | 36 kg |
General parameters | |||
Type | AL7F | ||
Band | 7 GHz | ||
Band | Licensed | ||
Frequency range (GHz) | 7.100 - 7.900 | ||
Duplex spacing (MHz) | 154, 160, 161, 168, 196, 245 | ||
Channel bandwidth (MHz) | 3.5 to 112 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 900 for MP400 (5 to 460 for MP300) full duplex | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Salomon | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters | |||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power max. (dBm) |
3.5 MHz / QPSK | 5 | -94 | 22 |
3.5 MHz / 8QAM | 8 | -90 | 22 |
3.5 MHz / 16QAM | 11 | -88 | 22 |
3.5 MHz / 32QAM | 14 | -83 | 22 |
3.5 MHz / 64QAM | 17 | -80 | 20 |
3.5 MHz / 128QAM | 20 | -77 | 20 |
3.5 MHz / 256QAM | 22 | -74 | 20 |
3.5 MHz / 512QAM | 25 | -71 | 20 |
3.5 MHz / 1024QAM | 27 | -66 | 20 |
7 MHz / QPSK | 11 | -90 | 22 |
7 MHz / 8QAM | 16 | -88 | 22 |
7 MHz / 16QAM | 22 | -84 | 22 |
7 MHz / 32QAM | 28 | -81 | 22 |
7 MHz / 64QAM | 33 | -78 | 20 |
7 MHz / 128QAM | 40 | -75 | 20 |
7 MHz / 256QAM | 44 | -72 | 20 |
7 MHz / 512QAM | 50 | -69 | 20 |
7 MHz / 1024QAM | 55 | -65 | 20 |
14 MHz / QPSK | 25 | -85 | 22 |
14 MHz / 8QAM | 35 | -83 | 22 |
14 MHz / 16QAM | 46 | -81 | 22 |
14 MHz / 32QAM | 58 | -77 | 22 |
14 MHz / 64QAM | 69 | -75 | 20 |
14 MHz / 128QAM | 81 | -72 | 20 |
14 MHz / 256QAM | 92 | -69 | 20 |
14 MHz / 512QAM | 104 | -66 | 20 |
14 MHz / 1024QAM | 115 | -63 | 20 |
28 MHz / QPSK | 50 | -82 | 22 |
28 MHz / 8QAM | 69 | -81 | 22 |
28 MHz / 16QAM | 92 | -77 | 22 |
28 MHz / 32QAM | 116 | -73 | 22 |
28 MHz / 64QAM | 139 | -72 | 20 |
28 MHz / 128QAM | 162 | -69 | 20 |
28 MHz / 256QAM | 185 | -66 | 20 |
28 MHz / 512QAM | 208 | -64 | 20 |
28 MHz / 1024QAM | 230 | -61 | 20 |
40 MHz / QPSK | 66 | -82 | 22 |
40 MHz / 8QAM | 100 | -80 | 22 |
40 MHz / 16QAM | 132 | -76 | 22 |
40 MHz / 32QAM | 165 | -74 | 22 |
40 MHz / 64QAM | 200 | -71 | 20 |
40 MHz / 128QAM | 232 | -68 | 20 |
40 MHz / 256QAM | 265 | -65 | 20 |
40 MHz / 512QAM | 300 | -62 | 20 |
40 MHz / 1024QAM | 330 | -59 | 20 |
56 MHz / QPSK | 100 | -80 | 22 |
56 MHz / 8QAM | 139 | -78 | 22 |
56 MHz / 16QAM | 185 | -75 | 22 |
56 MHz / 32QAM | 232 | -72 | 22 |
56 MHz / 64QAM | 278 | -69 | 20 |
56 MHz / 128QAM | 324 | -67 | 20 |
56 MHz / 256QAM | 370 | -64 | 20 |
56 MHz / 512QAM | 417 | -60 | 20 |
56 MHz / 1024QAM | 459 | -58 | 20 |
80 MHz / QPSK | 132 | -80 | 22 |
80 MHz / 8QAM | 200 | -76 | 22 |
80 MHz / 16QAM | 265 | -74 | 22 |
80 MHz / 32QAM | 330 | -70 | 22 |
80 MHz / 64QAM | 400 | -68 | 20 |
80 MHz / 128QAM | 463 | -64 | 20 |
80 MHz / 256QAM | 530 | -61 | 20 |
80 MHz / 512QAM | 600 | -59 | 20 |
80 MHz / 1024QAM | 660 | -55 | 20 |
112 MHz / QPSK | 184 | -77 | 22 |
112 MHz / 8QAM | 277 | -75 | 22 |
112 MHz / 16QAM | 369 | -72 | 22 |
112 MHz / 32QAM | 461 | -69 | 22 |
112 MHz / 64QAM | 553 | -66 | 20 |
112 MHz / 128QAM | 646 | -62 | 20 |
112 MHz / 256QAM | 740 | -60 | 20 |
112 MHz / 512QAM | 830 | -55 | 20 |
112 MHz / 1024QAM | 900 | -52 | 20 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antennas | |||
0.65 m gain mid band (dBi) | 31 | ||
0.90 m gain mid band (dBi) | 34 | ||
1.20 m gain mid band (dBi) | 37 | ||
Class | ETSI Class 2 or 3 | ||
Polarization | Vertical or horizontal | ||
Power supply | |||
Power supply | 48 V DC (36-72) | ||
Power consumption | Up to 25 W | ||
Temperature range | |||
Outdoor unit | -33 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 301 x 133 mm / 5.1 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg | ||
Antenna 0.65 m | 8.3 kg | ||
Antenna 0.90 m | 26 kg | ||
Antenna 1.20 m | 36 kg |
General parameters | |||
Type | AL8F | ||
Band | 8 GHz | ||
Band | Licensed | ||
Frequency range (GHz) | 7.725 - 8.500 | ||
Duplex spacing (MHz) | 119, 126, 151.614, 154, 208, 245, 266, 283.5, 310, 311.32 | ||
Channel bandwidth (MHz) | 3.5 to 112 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 900 for MP400 (5 to 460 for MP300) full duplex | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Salomon | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters | |||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power max. (dBm) |
3.5 MHz / QPSK | 5 | -94 | 22 |
3.5 MHz / 8QAM | 8 | -90 | 22 |
3.5 MHz / 16QAM | 11 | -88 | 22 |
3.5 MHz / 32QAM | 14 | -83 | 22 |
3.5 MHz / 64QAM | 17 | -80 | 20 |
3.5 MHz / 128QAM | 20 | -77 | 20 |
3.5 MHz / 256QAM | 22 | -74 | 20 |
3.5 MHz / 512QAM | 25 | -71 | 20 |
3.5 MHz / 1024QAM | 27 | -66 | 20 |
7 MHz / QPSK | 11 | -90 | 22 |
7 MHz / 8QAM | 16 | -88 | 22 |
7 MHz / 16QAM | 22 | -84 | 22 |
7 MHz / 32QAM | 28 | -81 | 22 |
7 MHz / 64QAM | 33 | -78 | 20 |
7 MHz / 128QAM | 40 | -75 | 20 |
7 MHz / 256QAM | 44 | -72 | 20 |
7 MHz / 512QAM | 50 | -69 | 20 |
7 MHz / 1024QAM | 55 | -65 | 20 |
14 MHz / QPSK | 25 | -85 | 22 |
14 MHz / 8QAM | 35 | -83 | 22 |
14 MHz / 16QAM | 46 | -81 | 22 |
14 MHz / 32QAM | 58 | -77 | 22 |
14 MHz / 64QAM | 69 | -75 | 20 |
14 MHz / 128QAM | 81 | -72 | 20 |
14 MHz / 256QAM | 92 | -69 | 20 |
14 MHz / 512QAM | 104 | -66 | 20 |
14 MHz / 1024QAM | 115 | -63 | 20 |
28 MHz / QPSK | 50 | -82 | 22 |
28 MHz / 8QAM | 69 | -81 | 22 |
28 MHz / 16QAM | 92 | -77 | 22 |
28 MHz / 32QAM | 116 | -73 | 22 |
28 MHz / 64QAM | 139 | -72 | 20 |
28 MHz / 128QAM | 162 | -69 | 20 |
28 MHz / 256QAM | 185 | -66 | 20 |
28 MHz / 512QAM | 208 | -64 | 20 |
28 MHz / 1024QAM | 230 | -61 | 20 |
40 MHz / QPSK | 66 | -82 | 22 |
40 MHz / 8QAM | 100 | -80 | 22 |
40 MHz / 16QAM | 132 | -76 | 22 |
40 MHz / 32QAM | 165 | -74 | 22 |
40 MHz / 64QAM | 200 | -71 | 20 |
40 MHz / 128QAM | 232 | -68 | 20 |
40 MHz / 256QAM | 265 | -65 | 20 |
40 MHz / 512QAM | 300 | -62 | 20 |
40 MHz / 1024QAM | 330 | -59 | 20 |
56 MHz / QPSK | 100 | -80 | 22 |
56 MHz / 8QAM | 139 | -78 | 22 |
56 MHz / 16QAM | 185 | -75 | 22 |
56 MHz / 32QAM | 232 | -72 | 22 |
56 MHz / 64QAM | 278 | -69 | 20 |
56 MHz / 128QAM | 324 | -67 | 20 |
56 MHz / 256QAM | 370 | -64 | 20 |
56 MHz / 512QAM | 417 | -60 | 20 |
56 MHz / 1024QAM | 459 | -58 | 20 |
80 MHz / QPSK | 132 | -80 | 22 |
80 MHz / 8QAM | 200 | -76 | 22 |
80 MHz / 16QAM | 265 | -74 | 22 |
80 MHz / 32QAM | 330 | -70 | 22 |
80 MHz / 64QAM | 400 | -68 | 20 |
80 MHz / 128QAM | 463 | -64 | 20 |
80 MHz / 256QAM | 530 | -61 | 20 |
80 MHz / 512QAM | 600 | -59 | 20 |
80 MHz / 1024QAM | 660 | -55 | 20 |
112 MHz / QPSK | 184 | -77 | 22 |
112 MHz / 8QAM | 277 | -75 | 22 |
112 MHz / 16QAM | 369 | -72 | 22 |
112 MHz / 32QAM | 461 | -69 | 22 |
112 MHz / 64QAM | 553 | -66 | 20 |
112 MHz / 128QAM | 646 | -62 | 20 |
112 MHz / 256QAM | 740 | -60 | 20 |
112 MHz / 512QAM | 830 | -55 | 20 |
112 MHz / 1024QAM | 900 | -52 | 20 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antennas | |||
0.65 m gain mid band (dBi) | 32 | ||
0.90 m gain mid band (dBi) | 35 | ||
1.20 m gain mid band (dBi) | 38 | ||
Class | ETSI Class 2 or 3 | ||
Polarization | Vertical or horizontal | ||
Power supply | |||
Power supply | 48 V DC (36-72) | ||
Power consumption | Up to 25 W | ||
Temperature range | |||
Outdoor unit | -33 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 301 x 133 mm / 5.1 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg | ||
Antenna 0.65 m | 8.3 kg | ||
Antenna 0.90 m | 26 kg | ||
Antenna 1.20 m | 36 kg |
General parameters | |||
Type | AL10F | ||
Band | 10 GHz | ||
Band | Licensed / License free | ||
Frequency range (GHz) | 10.000 - 10.680 | ||
Duplex spacing (MHz) | 91, 168, 350 or software configurable | ||
Channel bandwidth (MHz) | 3.5 to 56 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 459 for MP400 (5 to 250 for MP300) full duplex | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Salomon | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters | |||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power max. (dBm) |
3.5 MHz / QPSK | 5 | -95 | 9 |
3.5 MHz / 8QAM | 8 | -92 | 9 |
3.5 MHz / 16QAM | 11 | -88 | 9 |
3.5 MHz / 32QAM | 14 | -85 | 9 |
3.5 MHz / 64QAM | 17 | -81 | 6 |
3.5 MHz / 128QAM | 20 | -78 | 6 |
3.5 MHz / 256QAM | 22 | -75 | 6 |
3.5 MHz / 512QAM | 25 | -72 | 6 |
3.5 MHz / 1024QAM | 27 | -67 | 6 |
7 MHz / QPSK | 11 | -93 | 9 |
7 MHz / 8QAM | 16 | -89 | 9 |
7 MHz / 16QAM | 22 | -86 | 9 |
7 MHz / 32QAM | 28 | -83 | 9 |
7 MHz / 64QAM | 33 | -80 | 6 |
7 MHz / 128QAM | 40 | -77 | 6 |
7 MHz / 256QAM | 44 | -73 | 6 |
7 MHz / 512QAM | 50 | -70 | 6 |
7 MHz / 1024QAM | 55 | -66 | 6 |
14 MHz / QPSK | 25 | -89 | 9 |
14 MHz / 8QAM | 35 | -85 | 9 |
14 MHz / 16QAM | 46 | -83 | 9 |
14 MHz / 32QAM | 58 | -80 | 9 |
14 MHz / 64QAM | 69 | -77 | 6 |
14 MHz / 128QAM | 81 | -74 | 6 |
14 MHz / 256QAM | 92 | -71 | 6 |
14 MHz / 512QAM | 104 | -67 | 6 |
14 MHz / 1024QAM | 115 | -64 | 6 |
28 MHz / QPSK | 50 | -86 | 9 |
28 MHz / 8QAM | 69 | -82 | 9 |
28 MHz / 16QAM | 92 | -80 | 9 |
28 MHz / 32QAM | 116 | -77 | 9 |
28 MHz / 64QAM | 139 | -74 | 6 |
28 MHz / 128QAM | 162 | -71 | 6 |
28 MHz / 256QAM | 185 | -68 | 6 |
28 MHz / 512QAM | 208 | -64 | 6 |
28 MHz / 1024QAM | 230 | -61 | 6 |
40 MHz / QPSK | 66 | -84 | 9 |
40 MHz / 8QAM | 100 | -80 | 9 |
40 MHz / 16QAM | 132 | -77 | 9 |
40 MHz / 32QAM | 165 | -74 | 9 |
40 MHz / 64QAM | 200 | -71 | 6 |
40 MHz / 128QAM | 232 | -68 | 6 |
40 MHz / 256QAM | 265 | -65 | 6 |
40 MHz / 512QAM | 300 | -62 | 6 |
40 MHz / 1024QAM | 330 | -58 | 6 |
56 MHz / QPSK | 100 | -81 | 9 |
56 MHz / 8QAM | 139 | -79 | 9 |
56 MHz / 16QAM | 185 | -76 | 9 |
56 MHz / 32QAM | 232 | -73 | 9 |
56 MHz / 64QAM | 278 | -70 | 6 |
56 MHz / 128QAM | 324 | -67 | 6 |
56 MHz / 256QAM | 370 | -64 | 6 |
56 MHz / 512QAM | 417 | -61 | 6 |
56 MHz / 1024QAM | 459 | -57 | 6 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antennas | |||
0.35 m gain mid band (dBi) | 28 | ||
0.65 m gain mid band (dBi) | 34 | ||
0.90 m gain mid band (dBi) | 37 | ||
1.20 m gain mid band (dBi) | 40 | ||
Class | ETSI Class 2 or 3 | ||
Polarization | Vertical or horizontal | ||
Power supply | |||
Power supply | 48 V DC (36-72) | ||
Power consumption | Up to 25 W | ||
Temperature range | |||
Outdoor unit | -33 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 301 x 133 mm / 5.1 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg | ||
Antenna 0.35 m | 5.6 kg | ||
Antenna 0.65 m | 8.3 kg | ||
Antenna 0.90 m | 26 kg | ||
Antenna 1.20 m | 36 kg |
General parameters | |||
Type | AL11F | ||
Band | 11 GHz | ||
Band | Licensed | ||
Frequency range (GHz) | 10.700 - 11.700 | ||
Duplex spacing (MHz) | 490, 500, 530 | ||
Channel bandwidth (MHz) | 3.5 to 112 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 900 for MP400 (5 to 460 for MP300) full duplex | ||
Latency (ms) | < 0,09 for 900 Mbps | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Solomon FEC and Convolutional Interleaver | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters | |||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power max. (dBm) |
3.5 MHz / QPSK | 5 | -94 | 23 |
3.5 MHz / 8QAM | 8 | -91 | 23 |
3.5 MHz / 16QAM | 11 | -88 | 22 |
3.5 MHz / 32QAM | 14 | -84 | 22 |
3.5 MHz / 64QAM | 17 | -81 | 20 |
3.5 MHz / 128QAM | 20 | -78 | 20 |
3.5 MHz / 256QAM | 22 | -75 | 20 |
3.5 MHz / 512QAM | 25 | -71 | 20 |
3.5 MHz / 1024QAM | 27 | -68 | 20 |
7 MHz / QPSK | 11 | -91 | 23 |
7 MHz / 8QAM | 16 | -88 | 23 |
7 MHz / 16QAM | 22 | -85 | 22 |
7 MHz / 32QAM | 28 | -82 | 22 |
7 MHz / 64QAM | 33 | -79 | 20 |
7 MHz / 128QAM | 40 | -76 | 20 |
7 MHz / 256QAM | 44 | -73 | 20 |
7 MHz / 512QAM | 50 | -70 | 20 |
7 MHz / 1024QAM | 55 | -65 | 20 |
14 MHz / QPSK | 25 | -88 | 23 |
14 MHz / 8QAM | 35 | -85 | 23 |
14 MHz / 16QAM | 46 | -82 | 22 |
14 MHz / 32QAM | 58 | -79 | 22 |
14 MHz / 64QAM | 69 | -76 | 20 |
14 MHz / 128QAM | 81 | -73 | 20 |
14 MHz / 256QAM | 92 | -70 | 20 |
14 MHz / 512QAM | 104 | -67 | 20 |
14 MHz / 1024QAM | 115 | -63 | 20 |
28 MHz / QPSK | 50 | -85 | 23 |
28 MHz / 8QAM | 69 | -81 | 23 |
28 MHz / 16QAM | 92 | -78 | 22 |
28 MHz / 32QAM | 116 | -75 | 22 |
28 MHz / 64QAM | 139 | -72 | 20 |
28 MHz / 128QAM | 162 | -69 | 20 |
28 MHz / 256QAM | 185 | -66 | 20 |
28 MHz / 512QAM | 208 | -64 | 20 |
28 MHz / 1024QAM | 230 | -60 | 20 |
56 MHz / QPSK | 100 | -83 | 23 |
56 MHz / 8QAM | 139 | -79 | 23 |
56 MHz / 16QAM | 185 | -76 | 22 |
56 MHz / 32QAM | 232 | -73 | 22 |
56 MHz / 64QAM | 278 | -70 | 20 |
56 MHz / 128QAM | 324 | -67 | 20 |
56 MHz / 256QAM | 370 | -64 | 20 |
56 MHz / 512QAM | 417 | -60 | 20 |
56 MHz / 1024QAM | 459 | -57 | 20 |
80 MHz / QPSK | 132 | -81 | 23 |
80 MHz / 8QAM | 200 | -77 | 23 |
80 MHz / 16QAM | 265 | -75 | 22 |
80 MHz / 32QAM | 330 | -71 | 22 |
80 MHz / 64QAM | 400 | -68 | 20 |
80 MHz / 128QAM | 463 | -65 | 20 |
80 MHz / 256QAM | 530 | -62 | 20 |
80 MHz / 512QAM | 600 | -58 | 20 |
80 MHz / 1024QAM | 660 | -54 | 20 |
112 MHz / QPSK | 184 | -79 | 23 |
112 MHz / 8QAM | 277 | -75 | 23 |
112 MHz / 16QAM | 369 | -73 | 22 |
112 MHz / 32QAM | 461 | -69 | 22 |
112 MHz / 64QAM | 553 | -66 | 20 |
112 MHz / 128QAM | 646 | -63 | 20 |
112 MHz / 256QAM | 740 | -60 | 20 |
112 MHz / 512QAM | 830 | -56 | 20 |
112 MHz / 1024QAM | 900 | -52 | 20 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation with possibility of asymetric operation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antennas | |||
0.35 m gain mid band (dBi) | 29 | ||
0.65 m gain mid band (dBi) | 34.5 | ||
0.90 m gain mid band (dBi) | 38 | ||
1.20 m gain mid band (dBi) | 40 | ||
Class | ETSI Class 2 or 3 | ||
Polarization | Vertical or horizontal | ||
Power supply | |||
Power supply | 48 V DC (36-72), floating ground | ||
Power consumption | Up to 35 W | ||
Temperature range | |||
Outdoor unit | -35 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 301 x 133 mm / 5.1 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg | ||
Antenna 0.35 m | 6.5 kg | ||
Antenna 0.65 m | 8.9 kg | ||
Antenna 0.90 m | 26 kg | ||
Antenna 1.20 m | 36 kg |
General parameters | |||
Type | AL13F | ||
Band | 13 GHz | ||
Band | Licensed | ||
Frequency range (GHz) | 12.750 - 13.250 | ||
Duplex spacing (MHz) | 266 | ||
Channel bandwidth (MHz) | 3.5 to 112 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 900 for MP400 (5 to 460 for MP300) full duplex | ||
Latency (ms) | < 0,09 for 900 Mbps | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Solomon FEC and Convolutional Interleaver | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters | |||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power max. (dBm) |
3.5 MHz / QPSK | 5 | -94 | 23 |
3.5 MHz / 8QAM | 8 | -91 | 23 |
3.5 MHz / 16QAM | 11 | -88 | 22 |
3.5 MHz / 32QAM | 14 | -84 | 22 |
3.5 MHz / 64QAM | 17 | -81 | 20 |
3.5 MHz / 128QAM | 20 | -78 | 20 |
3.5 MHz / 256QAM | 22 | -75 | 20 |
3.5 MHz / 512QAM | 25 | -71 | 20 |
3.5 MHz / 1024QAM | 27 | -68 | 20 |
7 MHz / QPSK | 11 | -91 | 23 |
7 MHz / 8QAM | 16 | -88 | 23 |
7 MHz / 16QAM | 22 | -85 | 22 |
7 MHz / 32QAM | 28 | -82 | 22 |
7 MHz / 64QAM | 33 | -79 | 20 |
7 MHz / 128QAM | 40 | -76 | 20 |
7 MHz / 256QAM | 44 | -73 | 20 |
7 MHz / 512QAM | 50 | -70 | 20 |
7 MHz / 1024QAM | 55 | -65 | 20 |
14 MHz / QPSK | 25 | -88 | 23 |
14 MHz / 8QAM | 35 | -85 | 23 |
14 MHz / 16QAM | 46 | -82 | 22 |
14 MHz / 32QAM | 58 | -79 | 22 |
14 MHz / 64QAM | 69 | -76 | 20 |
14 MHz / 128QAM | 81 | -73 | 20 |
14 MHz / 256QAM | 92 | -70 | 20 |
14 MHz / 512QAM | 104 | -67 | 20 |
14 MHz / 1024QAM | 115 | -63 | 20 |
28 MHz / QPSK | 50 | -85 | 23 |
28 MHz / 8QAM | 69 | -81 | 23 |
28 MHz / 16QAM | 92 | -78 | 22 |
28 MHz / 32QAM | 116 | -75 | 22 |
28 MHz / 64QAM | 139 | -72 | 20 |
28 MHz / 128QAM | 162 | -69 | 20 |
28 MHz / 256QAM | 185 | -66 | 20 |
28 MHz / 512QAM | 208 | -64 | 20 |
28 MHz / 1024QAM | 230 | -60 | 20 |
56 MHz / QPSK | 100 | -83 | 23 |
56 MHz / 8QAM | 139 | -79 | 23 |
56 MHz / 16QAM | 185 | -76 | 23 |
56 MHz / 32QAM | 232 | -73 | 23 |
56 MHz / 64QAM | 278 | -70 | 20 |
56 MHz / 128QAM | 324 | -67 | 20 |
56 MHz / 256QAM | 370 | -64 | 20 |
56 MHz / 512QAM | 417 | -60 | 20 |
56 MHz / 1024QAM | 459 | -57 | 20 |
80 MHz / QPSK | 132 | -81 | 23 |
80 MHz / 8QAM | 200 | -77 | 23 |
80 MHz / 16QAM | 265 | -75 | 23 |
80 MHz / 32QAM | 330 | -71 | 23 |
80 MHz / 64QAM | 400 | -68 | 20 |
80 MHz / 128QAM | 463 | -65 | 20 |
80 MHz / 256QAM | 530 | -62 | 20 |
80 MHz / 512QAM | 600 | -58 | 20 |
80 MHz / 1024QAM | 660 | -54 | 20 |
112 MHz / QPSK | 184 | -79 | 23 |
112 MHz / 8QAM | 277 | -75 | 23 |
112 MHz / 16QAM | 369 | -73 | 23 |
112 MHz / 32QAM | 461 | -69 | 23 |
112 MHz / 64QAM | 553 | -66 | 20 |
112 MHz / 128QAM | 646 | -63 | 20 |
112 MHz / 256QAM | 740 | -60 | 20 |
112 MHz / 512QAM | 830 | -56 | 20 |
112 MHz / 1024QAM | 900 | -52 | 20 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation with possibility of asymetric operation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antennas | |||
0.35 m gain mid band (dBi) | 30 | ||
0.65 m gain mid band (dBi) | 35.5 | ||
0.90 m gain mid band (dBi) | 39 | ||
1.20 m gain mid band (dBi) | 41 | ||
Class | ETSI Class 2 or 3 | ||
Polarization | Vertical or horizontal | ||
Power supply | |||
Power supply | 48 V DC (36-72), floating ground | ||
Power consumption | Up to 35 W | ||
Temperature range | |||
Outdoor unit | -35 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 301 x 133 mm / 5.1 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg | ||
Antenna 0.35 m | 6.5 kg | ||
Antenna 0.65 m | 8.9 kg | ||
Antenna 0.90 m | 26 kg | ||
Antenna 1.20 m | 36 kg |
General parameters | |||
Type | AL17F | ||
Band | 17 GHz | ||
Band | License free | ||
Frequency range (GHz) | 17.100 - 17.300 | ||
Duplex spacing (MHz) | 110 to 190 | ||
Channel bandwidth (MHz) | 3.5 to 80 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 660 full duplex (10 to 1320 aggregate) for 1+0 | ||
Latency (ms) | < 0,11 for 660 Mbps | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Solomon FEC and Convolutional Interleaver | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters | |||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power (dBm) * |
3.5 MHz / QPSK | 5 | -95 | -24 to +12 |
3.5 MHz / 8QAM | 8 | -92 | -24 to +12 |
3.5 MHz / 16QAM | 11 | -89 | -24 to +12 |
3.5 MHz / 32QAM | 14 | -85 | -24 to +12 |
3.5 MHz / 64QAM | 17 | -82 | -24 to +5 |
3.5 MHz / 128QAM | 20 | -79 | -24 to +5 |
3.5 MHz / 256QAM | 22 | -76 | -24 to +5 |
3.5 MHz / 512QAM | 25 | -72 | -24 to +5 |
3.5 MHz / 1024QAM | 27 | -69 | -24 to +5 |
7 MHz / QPSK | 11 | -92 | -24 to +12 |
7 MHz / 8QAM | 16 | -89 | -24 to +12 |
7 MHz / 16QAM | 22 | -86 | -24 to +12 |
7 MHz / 32QAM | 28 | -83 | -24 to +12 |
7 MHz / 64QAM | 33 | -80 | -24 to +5 |
7 MHz / 128QAM | 40 | -77 | -24 to +5 |
7 MHz / 256QAM | 44 | -74 | -24 to +5 |
7 MHz / 512QAM | 50 | -71 | -24 to +5 |
7 MHz / 1024QAM | 55 | -66 | -24 to +5 |
14 MHz / QPSK | 25 | -89 | -24 to +12 |
14 MHz / 8QAM | 35 | -86 | -24 to +12 |
14 MHz / 16QAM | 46 | -83 | -24 to +12 |
14 MHz / 32QAM | 58 | -80 | -24 to +12 |
14 MHz / 64QAM | 69 | -77 | -24 to +5 |
14 MHz / 128QAM | 81 | -74 | -24 to +5 |
14 MHz / 256QAM | 92 | -71 | -24 to +5 |
14 MHz / 512QAM | 104 | -68 | -24 to +5 |
14 MHz / 1024QAM | 115 | -64 | -24 to +5 |
28 MHz / QPSK | 50 | -86 | -24 to +12 |
28 MHz / 8QAM | 69 | -82 | -24 to +12 |
28 MHz / 16QAM | 92 | -79 | -24 to +12 |
28 MHz / 32QAM | 116 | -76 | -24 to +12 |
28 MHz / 64QAM | 139 | -73 | -24 to +5 |
28 MHz / 128QAM | 162 | -70 | -24 to +5 |
28 MHz / 256QAM | 185 | -68 | -24 to +5 |
28 MHz / 512QAM | 208 | -65 | -24 to +5 |
28 MHz / 1024QAM | 230 | -61 | -24 to +5 |
56 MHz / QPSK | 100 | -84 | -24 to +12 |
56 MHz / 8QAM | 139 | -80 | -24 to +12 |
56 MHz / 16QAM | 185 | -79 | -24 to +12 |
56 MHz / 32QAM | 232 | -74 | -24 to +12 |
56 MHz / 64QAM | 278 | -70 | -24 to +5 |
56 MHz / 128QAM | 324 | -68 | -24 to +5 |
56 MHz / 256QAM | 370 | -65 | -24 to +5 |
56 MHz / 512QAM | 417 | -61 | -24 to +5 |
56 MHz / 1024QAM | 459 | -58 | -24 to +5 |
80 MHz / QPSK | 132 | -82 | -24 to +12 |
80 MHz / 8QAM | 200 | -78 | -24 to +12 |
80 MHz / 16QAM | 265 | -76 | -24 to +12 |
80 MHz / 32QAM | 330 | -72 | -24 to +12 |
80 MHz / 64QAM | 400 | -69 | -24 to +5 |
80 MHz / 128QAM | 463 | -66 | -24 to +5 |
80 MHz / 256QAM | 530 | -63 | -24 to +5 |
80 MHz / 512QAM | 600 | -59 | -24 to +5 |
80 MHz / 1024QAM | 660 | -55 | -24 to +5 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation with possibility of asymetric operation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antennas | |||
Horn gain mid band (dBi) | |||
0.35 m gain mid band (dBi) | 32.5 | ||
0.65 m gain mid band (dBi) | 38 | ||
0.90 m gain mid band (dBi) | 41.5 | ||
1.20 m gain mid band (dBi) | 43.5 | ||
Class | ETSI Class 2 or 3 | ||
Polarization | Dual | ||
Power supply | |||
Power supply | 48 V DC (36-72), floating ground | ||
Power consumption | Up to 25 W | ||
Temperature range | |||
Outdoor unit | -35 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 301 x 133 mm / 5.1 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg | ||
Horn antenna | kg | ||
Antenna 0.35 m | 6.5 kg | ||
Antenna 0.65 m | 8.9 kg | ||
Antenna 0.90 m | 26 kg | ||
Antenna 1.20 m | 36 kg | ||
* Production plant always sets the output power regarding on used antenna diameter to 100 mW (20 dBm) e.i.r.p |
General parameters | |||
Type | AL18F | ||
Band | 18 GHz | ||
Band | Licensed | ||
Frequency range (GHz) | 17.7 - 19.7 | ||
Duplex spacing (MHz) | 1010, 1560 | ||
Channel bandwidth (MHz) | 3.5 to 112 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 900 for MP400 (5 to 460 for MP300) full duplex | ||
Latency (ms) | < 0,09 for 900 Mbps | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Solomon FEC and Convolutional Interleaver | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters | |||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power max. (dBm) |
5 MHz / QPSK | 5 | -94 | 23 |
5 MHz / 8QAM | 8 | -91 | 23 |
5 MHz / 16QAM | 11 | -88 | 23 |
5 MHz / 32QAM | 14 | -84 | 23 |
5 MHz / 64QAM | 17 | -81 | 20 |
5 MHz / 128QAM | 20 | -78 | 20 |
5 MHz / 256QAM | 22 | -75 | 20 |
5 MHz / 512QAM | 25 | -71 | 20 |
5 MHz / 1024QAM | 27 | -68 | 20 |
7.5 MHz / QPSK | 11 | -91 | 23 |
7.5 MHz / 8QAM | 16 | -88 | 23 |
7.5 MHz / 16QAM | 22 | -85 | 23 |
7.5 MHz / 32QAM | 28 | -82 | 23 |
7.5 MHz / 64QAM | 33 | -79 | 20 |
7.5 MHz / 128QAM | 40 | -76 | 20 |
7.5 MHz / 256QAM | 44 | -73 | 20 |
7.5 MHz / 512QAM | 50 | -70 | 20 |
7.5 MHz / 1024QAM | 55 | -65 | 20 |
13.75 MHz / QPSK | 22 | -88 | 23 |
13.75 MHz / 8QAM | 34 | -84 | 23 |
13.75 MHz / 16QAM | 45 | -78 | 23 |
13.75 MHz / 32QAM | 56 | -76 | 23 |
13.75 MHz / 64QAM | 68 | -73 | 20 |
13.75 MHz / 128QAM | 78 | -70 | 20 |
13.75 MHz / 256QAM | 89 | -68 | 20 |
13.75 MHz / 512QAM | 100 | -65 | 20 |
13.75 MHz / 1024QAM | 112 | -61 | 20 |
27.5. MHz / QPSK | 45 | -83 | 23 |
27.5 MHz / 8QAM | 68 | -78 | 23 |
27.5 MHz / 16QAM | 90 | -76 | 23 |
27.5 MHz / 32QAM | 112 | -73 | 23 |
27.5 MHz / 64QAM | 135 | -70 | 20 |
27.5 MHz / 128QAM | 160 | -67 | 20 |
27.5 MHz / 256QAM | 180 | -64 | 20 |
27.5 MHz / 512QAM | 200 | -61 | 20 |
27.5 MHz / 1024QAM | 225 | -58 | 20 |
55 MHz / QPSK | 91 | -80 | 23 |
55 MHz / 8QAM | 135 | -75 | 23 |
55 MHz / 16QAM | 182 | -73 | 23 |
55 MHz / 32QAM | 230 | -70 | 23 |
55 MHz / 64QAM | 273 | -67 | 20 |
55 MHz / 128QAM | 320 | -64 | 20 |
55 MHz / 256QAM | 360 | -61 | 20 |
55 MHz / 512QAM | 410 | -58 | 20 |
55 MHz / 1024QAM | 450 | -54 | 20 |
110 MHz / QPSK | 180 | -77 | 23 |
110 MHz / 8QAM | 275 | -73 | 23 |
110 MHz / 16QAM | 365 | -70 | 23 |
110 MHz / 32QAM | 455 | -67 | 23 |
110 MHz / 64QAM | 545 | -64 | 20 |
110 MHz / 128QAM | 640 | -61 | 20 |
110 MHz / 256QAM | 730 | -58 | 20 |
110 MHz / 512QAM | 820 | -55 | 20 |
110 MHz / 1024QAM | 900 | -52 | 20 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation with possibility of asymetric operation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antennas | |||
0.35 m gain mid band (dBi) | 33 | ||
0.65 m gain mid band (dBi) | 38.5 | ||
0.90 m gain mid band (dBi) | 42 | ||
1.20 m gain mid band (dBi) | 44 | ||
Class | ETSI Class 2 or 3 | ||
Polarization | Vertical or horizontal | ||
Power supply | |||
Power supply | 48 V DC (36-72), floating ground | ||
Power consumption | Up to 35 W | ||
Temperature range | |||
Outdoor unit | -35 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 309 x 175 mm / 6.7 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg | ||
Antenna 0.35 m | 6.5 kg | ||
Antenna 0.65 m | 8.9 kg | ||
Antenna 0.90 m | 26 kg | ||
Antenna 1.20 m | 36 kg |
General parameters | |||
Type | AL24F | ||
Band | 24 GHz | ||
Band | License free | ||
Frequency range (GHz) | 24.000 - 24.250 | ||
Duplex spacing (MHz) | 190 or software configurable | ||
Channel bandwidth (MHz) | 3.5 to 112 | ||
Modulation scheme | QPSK to 1024QAM | ||
Transmission capacity (Mbps) | 5 to 900 for MP400 (5 to 460 for MP300) full duplex | ||
Latency (ms) | < 0,09 for 900 Mbps | ||
Frequency stability | < 10 ppm | ||
Forward error correction FEC | Reed-Solomon FEC and Convolutional Interleaver | ||
System configurations | 1+0, 1+1 or 2+0 (only 1+0 for MP300) | ||
Radio Parameters | |||
Bandwidth / modulation | Transmission capacity full duplex (Mbps) | Receiver sensitivity for 10-6 (dBm) | Output power (dBm) * |
3.5 MHz / QPSK | 5 | -94 | -27 to +5 |
3.5 MHz / 8QAM | 8 | -91 | -27 to +5 |
3.5 MHz / 16QAM | 11 | -88 | -27 to +5 |
3.5 MHz / 32QAM | 14 | -84 | -27 to +5 |
3.5 MHz / 64QAM | 17 | -81 | -27 to +5 |
3.5 MHz / 128QAM | 20 | -78 | -27 to +5 |
3.5 MHz / 256QAM | 22 | -75 | -27 to +5 |
3.5 MHz / 512QAM | 25 | -71 | -27 to +5 |
3.5 MHz / 1024QAM | 27 | -68 | -27 to +5 |
7 MHz / QPSK | 11 | -91 | -27 to +5 |
7 MHz / 8QAM | 16 | -88 | -27 to +5 |
7 MHz / 16QAM | 22 | -85 | -27 to +5 |
7 MHz / 32QAM | 28 | -82 | -27 to +5 |
7 MHz / 64QAM | 33 | -79 | -27 to +5 |
7 MHz / 128QAM | 40 | -76 | -27 to +5 |
7 MHz / 256QAM | 44 | -73 | -27 to +5 |
7 MHz / 512QAM | 50 | -70 | -27 to +5 |
7 MHz / 1024QAM | 55 | -65 | -27 to +5 |
14 MHz / QPSK | 25 | -88 | -27 to +5 |
14 MHz / 8QAM | 35 | -85 | -27 to +5 |
14 MHz / 16QAM | 46 | -82 | -27 to +5 |
14 MHz / 32QAM | 58 | -79 | -27 to +5 |
14 MHz / 64QAM | 69 | -76 | -27 to +5 |
14 MHz / 128QAM | 81 | -73 | -27 to +5 |
14 MHz / 256QAM | 92 | -70 | -27 to +5 |
14 MHz / 512QAM | 104 | -67 | -27 to +5 |
14 MHz / 1024QAM | 115 | -63 | -27 to +5 |
28 MHz / QPSK | 50 | -85 | -27 to +5 |
28 MHz / 8QAM | 69 | -81 | -27 to +5 |
28 MHz / 16QAM | 92 | -78 | -27 to +5 |
28 MHz / 32QAM | 116 | -75 | -27 to +5 |
28 MHz / 64QAM | 139 | -72 | -27 to +5 |
28 MHz / 128QAM | 162 | -69 | -27 to +5 |
28 MHz / 256QAM | 185 | -66 | -27 to +5 |
28 MHz / 512QAM | 208 | -64 | -27 to +5 |
28 MHz / 1024QAM | 230 | -60 | -27 to +5 |
56 MHz / QPSK | 100 | -83 | -27 to +5 |
56 MHz / 8QAM | 139 | -79 | -27 to +5 |
56 MHz / 16QAM | 185 | -76 | -27 to +5 |
56 MHz / 32QAM | 232 | -73 | -27 to +5 |
56 MHz / 64QAM | 278 | -70 | -27 to +5 |
56 MHz / 128QAM | 324 | -67 | -27 to +5 |
56 MHz / 256QAM | 370 | -64 | -27 to +5 |
56 MHz / 512QAM | 417 | -60 | -27 to +5 |
56 MHz / 1024QAM | 459 | -57 | -27 to +5 |
80 MHz / QPSK | 132 | -81 | -27 to +5 |
80 MHz / 8QAM | 200 | -77 | -27 to +5 |
80 MHz / 16QAM | 265 | -75 | -27 to +5 |
80 MHz / 32QAM | 330 | -71 | -27 to +5 |
80 MHz / 64QAM | 400 | -68 | -27 to +5 |
80 MHz / 128QAM | 463 | -65 | -27 to +5 |
80 MHz / 256QAM | 530 | -62 | -27 to +5 |
80 MHz / 512QAM | 600 | -58 | -27 to +5 |
80 MHz / 1024QAM | 660 | -54 | -27 to +5 |
112 MHz / QPSK | 184 | -79 | -27 to +5 |
112 MHz / 8QAM | 277 | -75 | -27 to +5 |
112 MHz / 16QAM | 369 | -73 | -27 to +5 |
112 MHz / 32QAM | 461 | -69 | -27 to +5 |
112 MHz / 64QAM | 553 | -66 | -27 to +5 |
112 MHz / 128QAM | 646 | -63 | -27 to +5 |
112 MHz / 256QAM | 740 | -60 | -27 to +5 |
112 MHz / 512QAM | 830 | -56 | -27 to +5 |
112 MHz / 1024QAM | 900 | -52 | -27 to +5 |
Automatic power control | ATPC | ||
ACM | Hitless Adaptive coding and modulation with possibility of asymetric operation | ||
User interfaces | |||
Protected terminal box | ALS1-GEth (RP) / ALS1-2GEth (RP) | ||
Line2 (only MP400) | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line3 | Ethernet 1000Base-T / 100Base-TX / 10Base-T, connector RJ-45 on terminal box | ||
Line4 (only MP400) | SFP slot for Ethernet 1000Base-SX / 1000Base-LX / 1000Base-BX / 1000Base-T or E1, connector on ODU | ||
Maximal packet length | 10240B for MP400 (2048B max for MP300) | ||
Supports | VLAN (only management on MP300), Auto Negotiation or manual setting 1000 / 100 / 10 and Full / Half Duplex, QoS, Flow Control, Auto MDIX, Master / Slave | ||
Control and diagnostic system | |||
Management port | Ethernet NMS separately or together with user data with possibility of VLAN separation | ||
Management port | RS232 connector on ODU for direct NMS connection | ||
Supports | SNMP v1 | ||
ODU connection | |||
Cable type | S-STP/S-FTP Cat.7 cable is conected to cutting strips “KRONE” both in ODU and protected terminal box | ||
Cable length | Up to 90 m for Ethernet 1000Base-T, up to 100 m for 100Base-TX and up to 250 m for 10Base-T | ||
Optical cable (only MP400) | Fibre optic cable is determinated by used SFP module | ||
Antennas | |||
Horn gain mid band (dBi) | |||
0.35 m gain mid band (dBi) | 35.5 | ||
0.65 m gain mid band (dBi) | 41 | ||
0.90 m gain mid band (dBi) | 44 | ||
1.20 m gain mid band (dBi) | 46 | ||
Class | ETSI Class 2 or 3 | ||
Polarization | Dual | ||
Power supply | |||
Power supply | 48 V DC (36-72), floating ground | ||
Power consumption | Up to 27 W | ||
Temperature range | |||
Outdoor unit | -35 to +55 °C | ||
Protected terminal box | -25 to +55 °C | ||
Dimensions (w x h x d) and weight | |||
Outdoor unit | 255 x 301 x 133 mm / 5.1 kg | ||
Protected terminal box | 147 x 44 x 163 mm / 0.4 kg | ||
Horn antenna | |||
Antenna 0.35 m | 6.5 kg | ||
Antenna 0.65 m | 8.9 kg | ||
Antenna 0.90 m | 26 kg | ||
Antenna 1.20 m | 36 kg | ||
* Production plant always sets the output power regarding on used antenna diameter to 100 mW (20 dBm) e.i.r.p. |